Menu
Your Cart
Corporate users can contact our email to provide special prices.

Ethernet or Wireless WiFi Communication Module for Delta DVP PLC

Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
Free Shipping
Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
Ethernet or Wireless WiFi Communication Module for Delta DVP PLC
$210.00
  • Stock: In Stock
  • Model: 2251832634033391
  • Weight: 0.30kg
  • SKU: 2251832634033391

Available Options

Buyer Protection
75-Day Buyer Protection Money back guarantee
About US/European Union VAT:
Goods purchased (<150€ with Free Shipping) from Wiseck and delivered to the destination located in the US/European Union (EU), VAT and duties(if applicable) have been included in their selling prices, and you don't need to pay additional tax. For more information about these costs, please contact the tax and customs authorities in your country.

For Delta DVP-ES / ES2 / EX2 / EC3 / EH3, DVP-SV2 / SS2 / SA / SX2, DVP-10PM / 20PM 

(The PLC in the pictures are NOT included.)

BCNet-DVP is an economical Ethernet communication processor, which is designed to meet the increasing demands of factory equipment informatization (equipment network monitoring and production management). It is used in Delta DVP-ES/ES2/EX2/EC3 /EH3, DVP-SV2/SS2/SA/SX2, DVP-10PM/20PM and other series of PLC Ethernet data acquisition, it is very convenient to build a production management system.

BCNet-DVP adopts a modular design, with a communication line from the factory. It does not occupy the PLC programming port, that is, while the programming software/host computer software monitors the PLC data through the Ethernet, the touch screen can communicate with the PLC through the multiplexing interface X2.


Module function

Installed on a 35mm guide rail, the COM1 port is directly connected to the MD8 programming communication round port of the DVP, and a COM2 port is extended for touch screen communication. BCNet-DVP can directly obtain power from the PLC programming communication port, or external 24VDC power supply.

Integrate a WEB server, through the web page, you can set device parameters and run diagnostics, and set a login protection password to prevent tampering with configuration data.

Automatically match PLC and HMI serial parameters without additional configuration.

Realize Ethernet communication with Delta programming software WPLSoft and ISPSoft, and perform program read/write (including RUN write function)/comparison, programmable controller operation monitoring and other functions through Ethernet.

It supports Delta Ethernet protocol communication, and can read/write device data to the programmable controller through the host computer system. After selecting the Delta Ethernet driver through the host computer software (KepWare OPC server, etc.), it is convenient Quick access.

Integrated ModbusTCP server, support FC1, FC2, FC3, FC5, FC6, FC16, the Modbus data area corresponds to the device address of Delta DVP.

The specific BCNetTCP/IP protocol is directly mapped to the serial port of the computer, and supports the convenient and quick access of the upper software (programming software FPWIN GR, IFIX, INTOUCH, KepWare OPC server, etc.).

By using ModbusTCP communication protocol or port mapping, high-level language (such as VB, VC, C#, etc.) programming can be realized, data communication with Delta DVP can be realized, and it is convenient to develop production management system.

SCADA (upper configuration software) supporting OPC channel communicates with PLC in OPC mode.

It can realize WPLSoft, ISPSoft, BCNetTCP transparent transmission, and ModbusTCP connection methods, allowing 6 PCs to collect PLC data at the same time, and the connection protocol method can be used arbitrarily.

Support firmware update on the user side through Ethernet, provide firmware with more functions for free, buy hardware once, and upgrade permanently.


Product numberBCNet-DVP
DescribeDelta DVP series PLC Ethernet communication processor
ColorMetallic Black
Status DisplayPwr,COM1,COM2,Link
Ethernet interface
Interface Type
Transmission rate
Protocol support
IEEE 802.3 compatible, Link/Active indicator, line sequence adaptive, support Auto-MDIX
RJ45 female socket
10/100Mbps
BCNetTCP、BCNetUDP
Number of TCP connections6
X1 interface (connected to PLC)
Interface Type
Transmission rate
Protocol support
RS232
MD8 communication female port
9.6K, 19.2K, 38.4K, 115.2Kbps
Delta PLC communication protocol
X2 interface (with HMI)
Interface Type
Transmission rate
Protocol support
RS232
MD8 communication female port
9.6K, 19.2K, 38.4K, 115.2Kbps
Delta PLC communication protocol
Configuration Software
OPC software
WPLSoft
Kingview, 3D Force Control, etc.
KepWare OPC
Diagnostics and Parameter settingIE browser, default 192.168.1.178, BCDevice
Power supply
Voltage type
Directly take power from the communication port or External 24VDC
24VDC/100mA
Operating temperature0~60℃
Working humidity90% non-condensing
Installation method35mm rail installation
Electromagnetic Compatibility2014/30/EU
Anti-vibration4.5mm/30Hz/10Min
ESD6KV
Factory agingThe 60-degree aging box runs for 168 hours, and the power is turned on and off 500 million times
Communication stabilityContinuous communication with PLC for 30 days, 130 million times of communication with 0 errors
CertificationCE Certification
Dimensions (LWH)90*24*65mm
Weight100g

BCNet-DVP-S is used for Ethernet data acquisition of Delta DVP-ES/ES2/EX2/EC3/EH3, DVP-SV/SS2/SA/SX2, DVP-10PM/20PM series PLC, which is very convenient to build production management system . The module integrates the WiFi function, supports AP mode, STA mode and AP+STA mode, which is very convenient to build a WiFi network, and perform PLC programming and data collection directly through WiFi. BCNet-DVP-S adopts a plug-and-play design and does not occupy the PLC communication port, that is, while the programming software/host computer software monitors the PLC data through Ethernet, the touch screen can communicate with the PLC through the multiplexing interface, supporting the industrial control field. Most SCADA software supports Delta Ethernet protocol and ModbusTCP communication method.

BCNet-DVP-S function

Installed on a 35mm guide rail, no external power supply required. The COM1 port is connected to the round port of the PLC, and the COM2 expansion port is used for touch screen communication.
Through the WEB server or the configuration diagnostic tool BCDevice, the device can be parameterized and run diagnostics.
Automatic identification of PLC model, automatic matching of PLC and HMI serial parameters, without additional configuration.
Integrated WiF function, support AP mode, STA mode and AP+STA mode
PLC programming data collection can be carried out through WiFi.
Realize Ethernet communication with Delta programming software WPLSoft and ISPSoft.
Support Delta Ethernet protocol communication, support access to host computer software (MCGS, KepWare OPC server, etc.).
Integrated ModbusTCP server, support FC1, FC2, FC3, FC5, FC6, FC16, Modbus data area is automatically mapped to PLC data area.
Using ModbusTCP, it can realize advanced language programming (such as VB, VC, C#, etc.), realize data communication with PLC, and facilitate the development of production management system.
The SCADA (upper configuration software) that supports OPC channel communicates with PLC in OPC mode.
It can realize WPLSoft, ISPSoft, ModbusTCP connection modes at the same time, and support the connection of 32 upper computers.
Support firmware update on the user side through Ethernet, one purchase, permanent upgrade.


Product numberBCNet-DVP-S
DescribeDelta DVP series PLC Ethernet communication processor
ColorMetallic Black
Status DisplayPwr, Coml,Com2, WiFi
Ethernet interface
Interface Type
output rate
Protocol support
Number of TCP connections
Link/Active indicator, automatic polarity crossover
RJ45 female socket
10/100Mbps
WPLSoft, ISPSoft^, ModbusTCP
up to 32
WiFi interface
Interface Type
transmit power
Receive sensitivity
Wireless type
Security Mechanism
Protocol support
Number of TCP connections
802.11 b/g/n 2.4G-2.5G
External high gain antenna
+26dBm(MAX,2.4G 802.11b/g/n)
-89d Bm (802.11b)x -74d Bm (802.11g)x -72d Bm (802.11n)
Station/AP mode
WPA-PSK/WPA2-PSK/WEP
FINS/UDP, FINS/TCP, ModbusTCP
up to 32
X1 interface (connected to PLC)
Interface Type
Transmission rate
Protocol support
RS232
MD8 communication female port
9.6K, 19.2K, 38.4K, 115.2Kbps
Delta PLC communication protocol
X2 interface (with HMI)
Interface Type
Transmission rate
Protocol support
RS232
MD8 communication female port
9.6K, 19.2K, 38.4K, 115.2Kbps
Delta PLC communication protocol
Configuration Software
OPC software
WPLSoft
Kingview, 3D Force Control, etc.
KepWare OPC
Diagnostics and Parameter settingIE browser, default 192.168.1.178, BCDevice
Power supply
Voltage type
Directly take power from the communication port or External 24VDC
24VDC/100mA
Operating temperature0~60℃
Working humidity90% non-condensing
Installation method35mm rail installation
Electromagnetic Compatibility2014/30/EU
Anti-vibration4.5mm/30Hz/10Min
ESD6KV
Factory agingThe 60-degree aging box runs for 168 hours, and the power is turned on and off 500 million times
Communication stabilityContinuous communication with PLC for 30 days, 130 million times of communication with 0 errors
CertificationCE Certification
Dimensions (LWH)115*27*75mm
Weight150g

Write a review

Note: HTML is not translated!
Bad Good

At Our Store, we accept all major credit cards and payments made through PayPal.

In addition, we support EUR, GBP, JPY, AED, CAD, AUD, SGD, you can use local currency to pay to the local receiving account. (contact support@wiseck.com sent you bill)

Standard Shipping 15-23 business days((Free Shipping)
Express Shipping 7-15 business days (contact support@wiseck.com sent you bill)

Corporate users can contact our email to provide special prices.
More Delivery Information

Tags: BCNet , ethernet