Goods purchased (<150€ with Free Shipping) from Wiseck and delivered to the destination located in the US/European Union (EU), VAT and duties(if applicable) have been included in their selling prices, and you don't need to pay additional tax. For more information about these costs, please contact the tax and customs authorities in your country.
BCNet-MB(RTU to ModbusTCP)
BCNet-MB is an economical Ethernet communication processor, which is designed to meet the increasing information requirements of factory equipment (equipment network monitoring and production management), and is used for Ethernet data acquisition (Modbus RTU/ASCII to Modbus TCP), it is very convenient to build a production management system.
The ModbusASCII/RTU master station can communicate with ModbusASCII/RTU devices through the multiplex interface, supports most SCADA software in the field of industrial control, and supports ModbusTCP and ModbusUDP communication methods.
BCNet-MB
Product number | Serial port type | Serial protocol | Ethernet protocol |
---|---|---|---|
BCNet-MB RS485 | RS485 | Modbus RTU/ASCII | Modbus TCP |
BCNet-MB RS232 | RS232 | Modbus RTU/ASCII | Modbus TCP |

BCNet-MB Features
Installed on a 35mm guide rail, directly connected to the RS485/RS232 interface of the Modbus RTU/ASCII device through a communication line, and connected to an external 24VDC power supply.
Integrate a WEB server, through the web page, you can set device parameters and run diagnosis, and set a login protection password to prevent tampering with configuration data.
This product is suitable for the network upgrade of Modbus RTU/ASCII, and can cooperate with the configuration software of the host computer supporting Modbus TCP to directly read the data of the device through this module.
Support asynchronous and uninterrupted Modbus TCP access mode, which is different from the traditional master-slave response half-duplex mode, providing more efficient data access. That is, the client’s Modbus TCP request can send multiple Modbus TCP requests at the same time without waiting for the reply from the device, and the module will automatically and asynchronously reply to the response frame.
The serial port supports RS485 and RS232 optional, and the baud rate supports 9600bps~115200bps optional.
2KV surge protection, ESD electrostatic protection, high-strength anti-electromagnetic interference.
When connected to Modbus RTU/ASCII slave station, multiple PCs are allowed to collect PLC data at the same time, and the real-time and reliability of data communication is fully guaranteed.
Support firmware update on the user side through Ethernet, provide firmware with more functions for free, purchase hardware once, and upgrade permanently.
Product number | BCNet-MB |
---|---|
Describe | Modbus Ethernet Communication Processor |
Color | Metallic Black |
Status Display | Pwr,COM1,COM2,Link |
Ethernet interface Interface Type output rate Protocol support Number of TCP connections | Link/Active indicator, automatic polarity crossover RJ45 female socket 10/100Mbps ModbusTCP 6 |
X1 interface (connected to PLC) Interface Type Transmission rate Protocol support | RS485 terminal 9.6K~115.2K Modbus RTU/ASCII |
X2 interface (with HMI) Interface Type Transmission rate Protocol support | RS485 terminal 9.6K~115.2K Modbus RTU/ASCII |
Configuration Software OPC software | Kingview, 3D Force Control, etc. KepWare OPC |
Diagnostics and Parameter setting | IE browser, default 192.168.1.178, BCDevice |
Power supply Voltage type | External 24V 24VDC/100mA |
Operating temperature | 0~60℃ |
Working humidity | 90% non-condensing |
Installation method | 35mm rail installation |
Electromagnetic Compatibility | 2014/30/EU |
Anti-vibration | 4.5mm/30Hz/10Min |
ESD | 6KV |
Factory aging | The 60-degree aging box runs for 168 hours, and the power is turned on and off 500 million times |
Communication stability | Continuous communication with PLC for 30 days, 130 million times of communication with 0 errors |
Certification | CE Certification |
Dimensions (LWH) | 90*24*65mm |
Weight | 100g |
BCNet-MB-S(RTU to ModbusTCP, wireless)
BCNet-MB-S is used for Ethernet data acquisition of ModbusASCII/RTU equipment (instrument, inverter, PLC, etc.), the module integrates WiFi function, supports AP mode, STA mode and AP+STA mode, which is very convenient to build WiFi network, directly ModbusASCII/RTU device programming and data acquisition via WiFi.
BCNet-MB-S adopts the plug-and-play design, which does not occupy the communication port of the ModbusASCII/RTU device, that is, while the programming software/host computer software monitors the device data through Ethernet, the ModbusASCII/RTU master station can communicate with the device through the multiplexing interface. ModbusASCII/RTU equipment for communication, supports most SCADA software in the field of industrial control, and supports ModbusTCP and ModbusUDP communication methods.

BCNet-MB-S Function
Installed on a 35mm guide rail, no external power supply required. The COM1 port is connected to the RS485 port of the device, and the COM2 expansion port is used for Modbus master communication.
Through the WEB server or the configuration diagnostic tool BCDevice, the device can be parameterized and run diagnostics.
It is suitable for the network upgrade of ModbusASCII/RTU, and the data of the device can be directly read through the configuration software of the host computer that supports ModbusTCP.
Integrated WiFi function, support AP mode, STA mode and AP+STA mode.
RS485/RS232 device data collection can be carried out through WiFi or Ethernet.
Support asynchronous and uninterrupted ModbusTCP access mode, which is different from the traditional master-slave response half-duplex mode, providing more efficient data access. That is, the client’s ModbusTCP request can send multiple ModbusTCP requests at the same time without waiting for the reply from the device, and the module will automatically and asynchronously reply to the response frame.
Support ModbusTCP, ModbusUDP, ModbusRTU and ModbusASCII communication protocols, support various configuration software and OPC, and access device data through Modbus protocol.
Using ModbusTCP/UDP, it can realize high-level language (such as VB, VC, C#, etc.) programming, realize data communication with PLC, and facilitate the development of production management system.
Support 32 ModbusTCP client connections.
Support firmware update on the user side through Ethernet, one purchase, permanent upgrade.
Product number | BCNet-MB-S |
---|---|
Describe | Modbus Ethernet Communication Processor |
Color | Metallic Black |
Status Display | Pwr,COM1,COM2,WiFi |
Ethernet interface Interface Type output rate Protocol support Number of TCP connections | Link/Active indicator, automatic polarity crossover RJ45 female socket 10/100Mbps ModbusTCP、ModbusUDP up to 32 |
WiFi interface Interface Type transmit power Receive sensitivity Wireless type Security Mechanism Protocol support number of connections | 802.11 b/g/n 2.4G-2.5G External high gain antenna +26dBm(MAX,2.4G 802.11b/g/n) -89dBm(802.11b), -74dBm(802.11g), -72dBm(802.11n) Station/AP mode WPA-PSK/WPA2-PSK/WEP ModbusTCP、ModbusUDP up to 32 |
X1 interface (connected to PLC) Interface Type Transmission rate Protocol support | RS485 terminal 9.6K, 19.2K, 38.4K, 57.6K, 115.2K ModbusRTU, ModbusASCII |
X2 interface (with HMI) Interface Type Transmission rate Protocol support | RS485 terminal 9.6K, 19.2K, 38.4K, 57.6K, 115.2K ModbusRTU, ModbusASCII |
Configuration Software OPC software | Kingview, 3D Force Control, etc. KepWare OPC |
Diagnostics and Parameter setting | IE browser, default 192.168.1.188, BCDevice |
Power supply Voltage type | External 24V 24VDC/100mA |
Operating temperature | 0~60℃ |
Working humidity | 90% non-condensing |
Installation method | 35mm rail installation |
Electromagnetic Compatibility | 2014/30/EU |
Anti-vibration | 4.5mm/30Hz/10Min |
ESD | 6KV |
Factory aging | The 60-degree aging box runs for 168 hours, and the power is turned on and off 500 million times |
Communication stability | Continuous communication with PLC for 30 days, 130 million times of communication with 0 errors |
Certification | CE Certification |
Dimensions (LWH) | 115*27*75mm |
Weight | 150g |
At Our Store, we accept all major credit cards and payments made through PayPal.
In addition, we support EUR, GBP, JPY, AED, CAD, AUD, SGD, you can use local currency to pay to the local receiving account. (contact support@wiseck.com sent you bill)
Standard Shipping 15-23 business days((Free Shipping)
Express Shipping 7-15 business days (contact support@wiseck.com sent you bill)
Corporate users can contact our email to provide special prices.
More Delivery Information